How to replace the Nova series DC tubes

How to replace the Nova series DC tubes

Firstly, turn off the whole machine power.


Video:

Instructions (may vary but the principle is the same):


Remove old part:


1. Unplug the wire between laser tube and laser power supply and take out from the hole, like below.



 


2.unfix the tube.      


① Cut the white ribbon




 


② Remove the screws




 


3.drain the water away from the tube.




 


Install new part:


In order to ensure laser path correct, location of new tube should be the same with the old one.





Then fix the tube and wire.


SEE ATTACHED PDF FOR LEGACY INSTRUCTIONS AND INFO ON SPLICING HV WIRES.


END


    • Related Articles

    • Nova Series User's Manual

      Please see attached: END
    • Inspecting and cleaning Nova series optics

      Thanks to Robert Kofoed for the video! This article is for Nova series machines. Proper care and routine maintenance of the machine will ensure optimal performance over a long service life. It is imperative that you remove, inspect, and clean your ...
    • Odin Series User's Manual

      Please see attached: END
    • Material Test for All CO2 Glass Tubes

      Test with 3mm plywood, LightBurn software,  Engraving(Fill) and Cutting(Line) modes , 60W, 80W, 100W, 130W tubes. Engraving(Fill) 60W 80W 100W 130W Cutting(Line) 60W 80W 100W 130W Material test file download The lbrn files are attached
    • Aurora Series User's Manual

      Aurora Series  User's Manual Please see attached Manuals for Aurora software Please refer this link:Manuals for Aurora software (thunderlaser.com.au) END