How to calibrate the working table to level

How to calibrate the working table to level


1. Two sides of the working table are not of the same height

Turn off the whole machine power, manually pull one of the belts of Z axis so as to adjust the up and down of the working table height of this side and calibrate the level in this way.


Shown as below:

 


2. One of the four corners that is of different height from the other three corners


As shown above, by adjusting these screws you can fine adjusting the support frame of the knife table so as to calibrate height of one corner. 


If neither of above two methods can solve the problem, please adjust according to below steps.

But it’s much more difficult. Please handle it carefully.

 3. Adjust the lead screws 

 

⑴ Loosen the screws of the fixed module. The belt will be loose accordingly.

⑵ Rotate the lead screws to calibrate the table height of this corner. (PS: rotate it clockwise, table in this corner will go up; turn it anticlockwise, table will go down)

⑶ Working table of this corner will go up or down when you rotate the lead screw in different directions.


 

End


    • Related Articles

    • Cutting problem-- Some point of the same piece of materials cannot be cut through

      Reasons: 1. The needed focus is lost Wrong focus length   For standard laser head(2" lens), the focus length is 6mm, 4 inch laser head, the focus length is 10mm. TYPE DOT SIZE FOCAL DISTANCE FUNCTION STANDARD 2" 0.0039″(0.099mm) 4.5mm~6.5mm Cutting ...
    • Engraving problem—The engraving quality is very poor

      Reasons: 1. The needed focus is lost Wrong focus length For standard laser head(2" lens), the focus length is 6mm, 4 inch laser head, the focus length is 10mm. TYPE DOT SIZE FOCAL DISTANCE FUNCTION STANDARD 2" 0.0039″(0.099mm) 4.5mm~6.5mm Cutting ...
    • How to remove the honey comb table

      The honey comb table needs to be cleaned after using for a period of time, how to remove it for clean, this video is for reference.
    • Aurora Series User's Manual

      Aurora Series  User's Manual Please see attached Manuals for Aurora software Please refer this link:Manuals for Aurora software (thunderlaser.com.au) END
    • Why USB connection is not working-RDWorks

      Reasons: 1. USB cable is loose or faulty Solution: Unplug the USB cable and plug it back, try again. If re-plug the cable, problem still exists. 2. USB driver is not installed successfully Before you install the software, please install the USB ...