Alarm message of LCD panel--Machine protected(Old type sensor)

Alarm message of LCD panel--Machine protected(Old type sensor)

Question:

LCD panel shows the following information:


Reasons:

1. The doors with sensor are not closed

Our machine has protection sensors for door (front cover and laser tube cover), like below.



Solution:

Please close all the doors before starting work.

2. The induction magnet is not in good position


If any of the sensor magnets is in bad position


Solution:

  • Take out these three magnets and directly place them on their sensors.



To better induct the magnet, please approach it on either side of the sensor, instead of the center.


  • Put position the magnets on sensors like above pic shown, check if the red light of "If protection on " disappears.



LCD panel→ Z/U button→ Diagnoses+ → “ If Protection on “

If it shows Red color: At least one of the three protection sensors is not working well (if all doors are closed).

If it shows Grey color: All protection sensors are working normally.

  • If the red color disappears, it proves one of the magnets was in bad position. 
  • Then please install the magnets back to the doors one by one to test which one causes the issue, then fine tuning the position for it. 


3. The wires of DrProc and GND on CN2 is loose from controller board




If the wires are tight, maybe the door sensor is bad. Please contact us:tech@thunderlaser.com.


End


    • Related Articles

    • Alarm message of LCD panel--Machine protected(New type sensor)

      Problem description: LCD panel shows the following information: Reasons: 1.The door with sensor not close Our machine has sensors for door protection, we've installed 5 door sensors totally. 2 mounted at top flap, 1 mounted at the front door, 1 ...
    • Alarm message of LCD panel-Water error

      Problem description: LCD panel shows the following information: Reasons: 1. Water chiller(water pump)is not turned on The switch in the red circle in the picture is not turned on. Solution: Please turn on the water chiller before power on the ...
    • Alarm message of LCD panel-Frame X/Y Slop over

      Problem description: LCD panel shows the following information: Reason: 1.The size of the graphic is larger than the working area of the machine Solution: If your laser cutter's working area is 600×400mm, but you want to cut a graphic which larger ...
    • Alarm message of LCD panel-No enough extend space

      Problem description: LCD panel shows the following information: Reason: 1.This problem only appears on engraving mode, it's caused by the buffer distance is out of bound.  For example, if you want to engrave a picture of 200×200mm, you move the laser ...
    • No response to LCD panel keys

      Problem description: When you turn on the machine, the machine can reset normally, but the buttons on the LCD panel do not respond when you click it. Reason: 1.The LCD panel cord is not firmly connected to the controller port. Solution: Unplug the ...